China's Mandatory Charging Standard GB 44263-2024: Mode 1 Banned, Connectors Must Sense Temperature

GB 44263-2024GB 44263-2024EV chargingcharging pilecharging connectormandatory standard

Anyone building charging equipment for the Chinese market has to deal with GB 44263-2024. It is a mandatory national standard, published 24 July 2024 and effective 1 August 2025 β€” now in force.

In one sentence: it defines what counts as a safe charging system β€” from how much current a plug may carry to whether the connector can sense temperature and lock in place.

Key facts

ItemDetail
DesignationGB 44263-2024
TitleSafety requirements for electric vehicle conductive charging system
Published2024-07-24
Effective2025-08-01 (in force)
StatusMandatory national standard
ClassificationICS 43.040.99, CCS T 35

Scope and voltage limits

It applies to AC and DC charging systems, with precise voltage boundaries:

  • Supply-side rated voltage: up to 1000 V AC or 1500 V DC
  • Vehicle-side rated maximum voltage: up to 1000 V AC or 1500 V DC
  • It also covers the charging safety requirements of bidirectional charging systems

Not covered: safety requirements related to maintenance, and automatic charging systems such as top-contact charging.

Structure: five safety dimensions

ClauseContent
5General requirements
6Charging connector safety
7AC charging safety
8DC charging safety
9Test methods
10Implementation of the standard
Annex ADC charging control pilot circuit for GB/T 20234.3 (normative)

The hardest rule: Mode 1 is banned

Clause 5.1.1 states:

Mode 1 as specified in 5.1 of GB/T 18487.1-2023 shall not be used to charge electric vehicles.

Mode 1 is charging directly from a socket with no control pilot. This is a prohibition at source, not a restriction.

Current limits by plug type

Clause 5.1.2 caps output current according to the plug:

Supply-side plugBasisOutput current limit
10 A single-phase two-pole with earthGB/T 2099.1, GB 1002No more than 8 A AC
16 A two-pole with earthNB/T 10202No more than 16 A AC
32 A plugGB/T 11918.1, GB/T 11918.2No more than 32 A AC

Note the first row: a 10 A plug may only deliver 8 A. This is the most common trap when specifying portable charging equipment.

Clause 5.1.3 adds that equipment used in unrestricted locations shall not use vehicle adapters that do not comply with the relevant national standards.

Connector protection level

Clause 6.1 requires protection against contact with hazardous parts:

  • Connection method B or C, vehicle plug mated with vehicle socket: IPXXD
  • Mode 3, connection method A or B, supply plug mated with supply socket: IPXXD

The "D" means a 1 mm test probe must not reach hazardous parts β€” including in the mated condition.

Connectors must sense temperature

Clause 6.2 requires temperature protection, graduated by current:

AC side:

  • AC supply equipment using connection method A or B with maximum charging current above 16 A AC must protect the supply socket
  • Three-phase AC equipment with maximum charging current above 32 A AC must protect the vehicle plug
  • EVs whose on-board charger has maximum charging current above 16 A AC must protect the vehicle socket

DC side:

  • DC supply equipment must monitor vehicle plug temperature, reducing power or triggering a fault stop when abnormal
  • EVs must provide vehicle socket temperature protection

This is the headline change: for high-power charging, over-temperature risk must now be actively monitored with power reduction at the equipment, not handled purely by passive protection.

Six functions required for AC charging (Clause 7)

Clause 7.1 requires:

  1. Control pilot β€” Mode 2 per GB/T 18487.1-2023 Annex A.1.2, Mode 3 per A.1.1
  2. Cable current-carrying capacity detection β€” confirm the cable's rated capacity via the resistance between detection point 3 and protective earth (Table A.5); charging current must not exceed the lower of supply capability and cable rating
  3. Supply capability signalling β€” PWM duty cycle tells the vehicle the available current (per Table A.2)
  4. Connector locking β€” during energy transfer, above 16 A AC the supply socket and vehicle socket must lock reliably
  5. Contactor welding detection β€” AC supply equipment must detect contactor welding; on single-phase L or any of L1/L2/L3 for three-phase, an alarm must be issued when stopping
  6. Short-circuit protection β€” a short before energy transfer means no charging; a short during transfer means charging stops

Clause 7.2 adds abnormal-charging protection, such as detecting the CC circuit condition at detection point 4.

An easily missed precondition

Clause 5.2 is explicit:

The precondition for implementing this document is that supply equipment complies with GB 39752 and electric vehicles comply with GB 18384.

So charging system safety (this standard) builds on supply equipment safety (GB 39752) and vehicle safety (GB 18384). Certifying this standard alone leaves the chain incomplete.

Relation to GB/T 18487.1

  • GB/T 18487.1-2023: general requirements for conductive charging systems β€” recommended, covering system architecture and control pilot design
  • GB 44263-2024: safety requirements β€” mandatory, covering the safety floor and test methods

One says how to build it, the other says what it must achieve. Products need both, but only the latter is mandatory.

Export equivalents

  • EU: IEC 61851 series, adopted as EN 61851; the complete charger also falls under the Low Voltage Directive and EMC Directive
  • US: UL 2594 for AC charging, UL 2202 for DC charging
  • Connectors: China uses GB/T 20234, Europe Type 2 / CCS2, the US CCS1 / NACS

Connector incompatibility is a hard barrier β€” changing markets means changing connectors and re-testing.

Four practical tips

  1. Check the plug configuration first β€” the 10 A plug / 8 A output rule is the easiest to breach on portable equipment.
  2. Build temperature sensing into high-power products β€” required above 16 A AC and on the DC side; it is mandatory, not optional.
  3. Do not skip locking and welding detection β€” locking above 16 A, plus welding detection with alarm.
  4. Have the prerequisite standards ready β€” GB 39752 and GB 18384 underpin this one.

The full GB 44263-2024 text (Clause 6 connector safety, Clause 7 AC charging safety, Clause 9 test methods, Annex A control pilot circuit), along with GB 39752, GB 18384 and GB/T 18487.1, is in the StdFlow knowledge base. Sign up and ask an AI agent for the original text β€” every answer cited.

FAQ

When did GB 44263-2024 take effect?

Published 24 July 2024 and effective 1 August 2025. It is a mandatory national standard and is now in force.

Which products does it apply to?

AC and DC charging systems for electric vehicles, where the supply-side rated voltage is up to 1000 V AC or 1500 V DC and the vehicle-side rated maximum voltage is within the same limits. It also covers the charging safety requirements of bidirectional charging systems. It does not cover maintenance safety or automatic charging systems such as top-contact charging.

Why is Mode 1 charging banned?

Clause 5.1.1 states that Mode 1 as defined in GB/T 18487.1-2023 shall not be used for charging. Mode 1 has no control pilot, so it is prohibited at the source rather than merely restricted.